Project Description

The proposed project deals with the influence of flow disturbances on meters for water flow. The influences of some hydraulic disturbances will be investigated with respect to

  • changes in error characteristics and
  • changes in the flow profiles
     

For this purpose two diameters are chosen: DN 40 and DN 50 and some measurement principles like winged wheel water meters, electromagnetic meters, ultrasonic meters and Woltman-meters.
For detection of changes in flow profiles a Laser-Doppler-Velocimeter (LDV) will be used.

The measurements was started in 2003 with the installation of a LDV-system in the BEV. Some supported measurements are made in autumn 2004 in the PTB/Berlin.


Final Report 2007-06-01

The project has been completed and the report can be downloaded here>>.

The purpose of this project was to examine the influence of installations effects on water flow sensors.
Sources of disturbances were half opened ball pipes, 90° elbows, spatial elbows as well as pipe confusers and diffusors.