PRAQIII Intercomparison of electrical measurements
Project Descrition
NMIs of all 13 PHARE countries took part in an electrical comparison, using the 1,018 V and 10 V outlets of a FLUKE 732B DC reference standard and two Guildline 9334 resistors of 10 Ohm and 10 kOhm. The project was coordinated by the NMi.
Final Report 2000-08-01
The original report was summarised to comply with EUROMET guidance document no 3. A Summary has been submitted to the Rapporteur for the consideration of publishing in Metrologia.
For a full account of the comparison, see F. Liefrink, Organisation of measurement intercomparison - Electrical measurements, NMi ID-nr: B5-97-030